CUH SDVC31-M VIBRATOR CONTROLLER
Product Specifications
- Product Type Vibrator Controller
- Application best vibration frequency of the vibratory feeder to get smooth, quiet and energy-saving feed effect.
- Protection Level IP67
- Frequency (MHz) 40 – 400 Hz Hertz (HZ)
- Rated Voltage 85 260 V Volt (V)
- Energy Consumption 1.5- 3 W Energy
- Output Type Users can adjust output frequency of the controller to best vibration frequency of the vibratory feeder to get smooth, quiet and energy-saving feed effect.
- Color black- grey
- Dimension(L*W*H) 190*53.6*94.5(L*W*H, mm) Millimeter (mm)
- Weight SDVC31-S:560g(without accessory) / SDVC31-M:610g(without accessory) Grams (g)
- Warranty 1 year
Product Description
Features
Automatic Voltage Regulation : Eliminate both feed speed variation causea by mains voltage fluctuation and beat effect caused by industrial AC frequency.
Soft Startup : In order to avoid sudden shock to lhe feed material and vibratory feeder, the controller can gently increase output voltage from 0 to the preset value when startup.
Remote ON/OFF Control : The controller has 2 groups of ON/OFF conlrol ports. Switch sensor ot PLC can be connected to them to turn on/off the controller.
Photoelectric ON/OFF Control : The CUH Intelligent Photoelectric Sensor can be connected to turn on/off the controller.
Remote Speed Control : Output Voltage of the controller can be adjusted remotely by an external potentiometer. a PLC. or a 1-5V DC signal.
24V DC Control Output : The controller can output 24V DC power associated with logical relation setting of the ON/OFF Control to drive a solenoid, an electrical relay or other external devices
Control Panel lock : Lock all buttons on the conttol panel by pressing the ON/OFF button and hold for 2 seconds to prevent misoperation.
Max Adjustable Output Voltage : Max Adjustable Output Voltage can be preset to protect the vibratory feeder from damage caused by high voltage.
Overheat Protection : If internal temperature of the controller gets too high. the conttoller will stop its output to protect itself.
Overcurrent Protection : If output current exceeds its rated value by Misoperation, the controller Will stop its output to protect the controller and vibratoty feeder.
Short-Circuit Protection : lf output of the controller is short -circuited, the fuse inside the controller will be blown to protect the controller and vibratory feeder from further damage.
Technical Specifications
ITEM | Range | Unit | Description | |
Min | Max | |||
Input voltage | 85 | 260 | V | AC RMS Value |
Output voltage | 0 | 260 | V | Less than 150% of Input voltage |
Output Current | 0 | 1.5 | A | SDVC31-S |
0 | 3.0 | A | SDVC31-M | |
Output Frequency | 40 | 400 | HZ | |
OutPut Power | 0 | 330 | VA | SDVC31-S |
0 | 660 | VA | SDVC31-M | |
Output Waveform | Sine | |||
Voltage adjustmen Accuracy | 1 | V | ||
Frequency Adjustment Accuracy | 0.1 | Hz | ||
ON/OFF delay | 0 | 20 | s | |
ON/OFF Delay Accuracy | 0.1 | s | ||
Soft Startup Time | 0 | 10 | s | |
DC Control output Voltage | 22 | 26 | V | DC output associated with ON/OFF control |
DC Control output current | 0 | 200 | mA | |
Stand by Power Consumption | 1.5 | 3 | w | |
Display Method | 5 | Digit | LED Digital Tube | |
Control Method | 1-5 | V | Remote Speed
Control Voltage |
|
Standard TTL Electric Level | Switching Signal | |||
6 Buttons + 2LED screens | ||||
Work Space Temperature |
-10 | 60 | C |
Non-Condensing |
Work Space Humidity | 10 | 85 | % |
Reviews
There are no reviews yet.